Panelview 600 Show Write Fail and Read Fail Using Controlnet

NOTE: Check out the new version of this article HERE.

PanelView Plus 700I yet run into clients who are merely beginning to utilise the PanelView Plus, even though it was released a decade ago.

So for all everyone out in that location who is new to the PanelView Plus, hither are 7 things you need to know:

1) PanelView Plus hardware features:

PanelView Plus 700-1500
PanelView Plus 700 – 1500

The original PanelView Plus came in four different versions, all of which support upto firmware version 5.1.

Note: PanelView Plus models loaded with newer firmware practise back up older runtime projects, all the fashion back to v3.0. This means there is no demand to downgrade the panel's firmware to gain legacy support. In fact, some newer console can not be downgraded to older firmware.

All terminals include (at a minimum) a CompactFlash Card slot, a USB Port, and a DB9 Serial Port. Most terminals also came in Touchscreen only, Keypad merely, and Touchscreen/Keypad combination units.

  • PanelView Plus 700, yard, 1250, 1500 (seven″ to fifteen″ displays)
    • The original and standard PanelView Plus with replaceable bezels and modular construction.
  • VersaView CE / PanelView Plus CE 700, one thousand, 1250, 1500 (7″ to fifteen″ displays)
    • Identical to the PanelView Plus, but with more memory and the Windows CE OS exposed
  • PanelView Plus 400 and 600 (4″ and 6″ displays)
    • A smaller, all plastic version of the PanelView Plus
  • PanelView Plus Compact
    • Lower price, DC only versions of the four″, 6″, and x″ PanelView Plus.
    • Reduced software functionality includes 1 PLC, 25 display, and 200 alarm limits.
    • None of these units support add-on communications modules.

two) PanelView Plus 6 hardware features:

PanelView Plus 400 and 600
PanelView Plus 6, 400 & 600

The new PanelView Plus 6 comes in four unlike versions besides, and well-nigh support firmware versions 6.0 – 7.0.

However, ane big deviation is none of these units back up IO networks. Specifically, PanelView Plus 6 terminals exercise not support RIO, DeviceNet, and scheduled ControlNet.

PanelView Plus 6 models practice back up all runtime file versions back to 3.ii. That is, as long as the runtime is using a supported advice path (see note above.)

These units include (at a minimum) an SD Card slot, a USB Port, and a DB9 Serial Port. Virtually terminals also come in Touchscreen only, Keypad only, and Touchscreen/Keypad combination units.

  • PanelView Plus six (standard) 700, thousand, 1250, 1500 (seven″ to xv″)
    • Similar the original, only with more horsepower, retention, and Window CE.
  • PanelView Plus 6 Enhanced 700, 1000, 1250, 1500 (vii″ to xv″)
    • Identical to the PanelView Plus half dozen (standard) simply with Windows Media Player, Internet Explorer, and Microsoft Office viewers
  • PanelView Plus 6 400 and 600 (4″ and six″)
    • Like to the original simply with some of the added PanelView Plus vi features
    • Unlike the original, none of these units back up addition communications modules.
  • PanelView Plus 6 Meaty
    • Aforementioned restrictions as the PVPlus Compact, simply with some of the new features of the PanelView Plus 6.
    • Currently simply available in 4″ and 6″ models.

three) Every PanelView Plus comes preloaded with FactoryTalk View Car Edition Runtime software and license.

Every PanelView Plus has a licensed re-create of the ViewME runtime software pre-installed. This software runs ".mer" runtime project files created on a PC using the FactoryTalk ViewStudio development software (formerly RSViewStudio.)

RSLinx Enterprise in ViewStudio Project4) Communications from ViewStudio to the PanelView Plus and Allen-Bradley programmable controllers requires RSLinx Enterprise

Communications from FactoryTalk ViewStudio to the PanelView Plus, and from the PanelViewPlus or ViewStudio to an Allen-Bradley programmable controller, requires RSLinx Enterprise. FactoryTalk ViewStudio comes with RSLinx Enterprise and it'south highly recommended you install it forth with ViewStudio.

5) RSLinx Communications setup consists of two configurations: Local and Target

For the ViewStudio project components (graphic displays, alarms, trends, etc) to communicate with an A-B programmable controller, you'll need to configure the RSLinx Enterprise communications setup. This setup consists of two sections:

  • The Local/Development tab is for the communications from ViewStudio to an A-B programmable controller, as well as from the Transfer Utility to the PanelView Plus.
  • The Target/Runtime tab is for communications from the PanelView Plus to an A-B programmable controller.

RSLinx Enterprise Communications Setup Window

6) After calculation or changing tags, exist sure to "refresh all folders."

After you change or add to your HMI tags, programmable controller tags, or RSLinx Enterprise communications setup, be sure to right click in the tag browser and "Refresh all folders" in order to browse for new tags in ViewStudio.

ViewStudio Tag Browser Refresh All Folders

vii) Be certain to bank check "run on startup" and "replace communications" when using the Transfer Utility to download to the PanelView Plus.

You lot tin can transfer your ViewStudio ME .mer runtime file through RSLinx Enterprise to your PanelViewPlus using the included Transfer Utility. However, exist certain to check the "run on start-up" and "replace communications" checkboxes. This insures your project starts when the PanelView Plus starts, and that your project'due south communication settings supercede the previous terminal settings.

Transfer Utility BannerI hope you've constitute these vii tips for using the PanelView Plus helpful.

If you lot'd like to add together your ain tips to this list simply reply to this mail service using the "postal service a annotate or question" link below.

Sincerely,

Shawn Tierney
Automation Instructor and Blogger

Have a question? Join my community of automation professionals and take office in the give-and-take! Yous'll besides find my PLC, HMI, and SCADA courses at TheAutomationSchool.com.

Sponsor and Annunciate: Get your product or service in front of our 70K followers while also supporting contained automation journalism past sponsoring or advertizement with us! Learn more in our Media Guide here, or contact the states using this form or by calling our role at 413-749-4300.

  • Author
  • Contempo Posts

(55,077 views)

fieldsliffeccand.blogspot.com

Source: https://theautomationblog.com/seven-things-you-need-to-know-before-using-the-panelview-plus/

0 Response to "Panelview 600 Show Write Fail and Read Fail Using Controlnet"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel